氫氧化鉀檢測的細(xì)節(jié)與注意的地方

發(fā)布來源:http://www.shrisa.cn    更新時間:2023-01-31 點擊數(shù):33

檢驗氫氧化鉀中要確定樣品的采樣單元數(shù)。采樣器由袋口的一角斜到袋深的3/4處采樣,將采出的樣品混勻,用四分法縮分到所要檢驗的樣品量。
The number of sampling units of the sample shall be determined in the test of potassium hydroxide. The sampler slants from one corner of the bag mouth to 3/4 of the bag depth for sampling, mixes the collected samples evenly, and reduces them to the amount of samples to be tested by quartering.
因氫氧化鉀肥料吸水性強,故在制備樣品時動作應(yīng)迅速。樣品制備后,稱取5g試樣,到0.001g,加入150ml水,然后在不斷攪拌下加熱,微沸5min,取下冷卻到20℃,移入500ml容量瓶,定容過濾后再吸取25.0ml于250.0ml的容量瓶中。這是一個很關(guān)鍵的環(huán)節(jié)。
Because potassium hydroxide fertilizer has strong water absorption, it should be rapid when preparing samples. After sample preparation, weigh 5g of sample to 0.001g, add 150ml of water, and then heat it under constant stirring, slightly boil it for 5min, take it down and cool it to 20 ℃, transfer it into a 500ml volumetric flask, filter at constant volume, and then suck 25.0ml into a 250.0ml volumetric flask. This is a key link.
有一些檢驗員為了一時方便,不是在水溫達(dá)到20℃時定容,而按常溫的水溫定容,結(jié)果是水溫高于20℃時,結(jié)果偏高;水溫低于20℃時,結(jié)果偏低。兩次定容造成兩次誤差,所以,準(zhǔn)確的檢驗溫度是檢驗結(jié)果準(zhǔn)確與否的關(guān)鍵。水溫高于20℃的檢驗結(jié)果與20℃時的檢驗結(jié)果比較見表1。
For temporary convenience, some inspectors do not fix the volume when the water temperature reaches 20 ℃, but according to the normal temperature. The result is that when the water temperature is higher than 20 ℃, the result is higher; When the water temperature is lower than 20 ℃, the result is low. Two times of constant volume cause two times of error, so the accurate test temperature is the key to the accuracy of the test results. See Table 1 for the comparison of the test results when the water temperature is higher than 20 ℃ and the test results when the water temperature is 20 ℃.
氫氧化鉀
在弱堿性介質(zhì)中,四苯硼鈉[NaB(C6H5)4]堿性溶液和洗滌液對檢驗結(jié)果有直接影響。因為配制好的四苯硼鈉很不穩(wěn)定,容易產(chǎn)生渾濁。如果使用前發(fā)現(xiàn)有混濁,要用中速濾紙過濾后再使用,否則檢驗結(jié)果偏高。用洗滌液洗滌和用蒸餾水洗滌檢驗,結(jié)果也不一樣。有些檢驗員認(rèn)為配制洗滌液麻煩,用蒸餾水代替洗滌液,檢驗結(jié)果就會偏低。蒸餾水的原始結(jié)果與洗滌劑的正確結(jié)果相關(guān)數(shù)據(jù)比較見表1。
In weakly alkaline medium, sodium tetraphenylboron [NaB (C6H5) 4] alkaline solution and washing solution have a direct impact on the test results. Because the prepared sodium tetraphenylboron is unstable and easy to produce turbidity. If turbidity is found before use, it should be filtered with medium speed filter paper before use, otherwise the test result is on the high side. The results of washing with detergent and distilled water are also different. Some inspectors think it is troublesome to prepare washing solution. If distilled water is used instead of washing solution, the test result will be low. See Table 1 for the comparison between the original results of distilled water and the correct results of detergent.
檢驗中,試液過濾后的洗滌步驟存在洗滌終點不夠明確的問題。依據(jù)GB6549-1996《氫氧化鉀》規(guī)定,先抽濾上清液,再用洗滌液(即室溫下飽和的四苯硼鉀溶液)轉(zhuǎn)移沉淀過濾器中,繼續(xù)用以上洗滌液洗滌沉淀12次左右,每次洗滌液用量約為5ml。
During the test, there was a problem that the washing end point was not clear enough in the washing step after the test solution was filtered. According to the provisions of Potassium Hydroxide (GB6549-1996), the supernatant is filtered first, and then the washing solution (i.e. potassium tetraphenylborate solution saturated at room temperature) is transferred to the filter for precipitation. The above washing solution is used to wash and precipitate for about 12 times, and the amount of washing solution is about 5ml each time.
如果檢驗員做不夠洗滌次數(shù),在干燥后的坩堝上就能清晰見到粉紅色的物質(zhì),這是未洗滌盡的氫氧化鈉與酚酞產(chǎn)生的物質(zhì)顏色,終將導(dǎo)致鉀含量偏高。因此,洗滌次數(shù)均不應(yīng)低于12次。洗滌次數(shù)少于12次的原始結(jié)果與不少于12次的正確結(jié)果比較見表1。
If the inspector does not wash enough, the pink substance can be clearly seen on the dried crucible. This is the color of the substance produced by the unwashed sodium hydroxide and phenolphthalein, which will eventually lead to a high potassium content. Therefore, the washing times should not be less than 12 times. See Table 1 for the comparison between the original results of less than 12 times of washing and the correct results of no less than 12 times.
總結(jié)一下在氫氧化鉀產(chǎn)品的主含量氧化鉀檢驗中,對幾個關(guān)鍵環(huán)節(jié)必須給予足夠的重視,對可能產(chǎn)生誤差的各種因素要加以避免和克服,才能保證檢驗結(jié)果的準(zhǔn)確度。
To sum up, in the test of potassium oxide in the main content of potassium hydroxide products, sufficient attention must be paid to several key links, and various factors that may cause errors must be avoided and overcome to ensure the accuracy of the test results.
以上闡述的就是氫氧化鉀檢測的細(xì)節(jié)與注意的地方,希望我的分享對你們有所幫助,如果還想了解更多相關(guān)內(nèi)容請繼續(xù)關(guān)注我們網(wǎng)站http://www.shrisa.cn,后期我們也會發(fā)布更多相關(guān)咨詢。當(dāng)然有什么不懂的地方歡迎您前來電話咨詢。
The above is the details and points for attention of potassium hydroxide detection. I hope my sharing will help you. If you want to know more, please continue to pay attention to our website http://www.shrisa.cn , we will also release more relevant consultation later. Of course, if you don't understand anything, you are welcome to call.

聯(lián)系我們

濟(jì)南金昊化工有限公司

電話:13869119097

傳真:0531-88529097

售后:0531-88529097

地址:濟(jì)南市天橋區(qū)桑梓店鎮(zhèn)化工市場南區(qū)

掃描二維碼,關(guān)注我們

13869119097

全國客戶服務(wù)熱線

濟(jì)南金昊化工有限公司

備案號:魯ICP備19046505號-2
主站蜘蛛池模板: 产业规划_产业园区规划-产业投资选址及规划招商托管一体化服务商-中机院产业园区规划网 | 流程管理|流程管理软件|企业流程管理|微宏科技-AlphaFlow_流程管理系统软件服务商 | 耐酸碱泵-自吸耐酸碱泵型号「品牌厂家」立式耐酸碱泵价格-昆山国宝过滤机有限公司首页 | 礼至家居-全屋定制家具_一站式全屋整装_免费量房设计报价 | 无纺布包装机|径向缠绕包装机|缠绕膜打包机-上海晏陵智能设备有限公司 | 篮球地板厂家_舞台木地板品牌_体育运动地板厂家_凯洁地板 | 集装箱箱号识别_自重载重图像识别_铁路车号自动识别_OCR图像识别 | 铝镁锰板_铝镁锰合金板_铝镁锰板厂家_铝镁锰金属屋面板_安徽建科 | CTP磁天平|小电容测量仪|阴阳极极化_双液系沸点测定仪|dsj电渗实验装置-南京桑力电子设备厂 | 振动传感器,检波器-威海广达勘探仪器有限公司| 杭州厂房降温,车间降温设备,车间通风降温,厂房降温方案,杭州嘉友实业爽风品牌 | 余姚生活网_余姚论坛_余姚市综合门户网站| 会议会展活动拍摄_年会庆典演出跟拍_摄影摄像直播-艾木传媒 | vr安全体验馆|交通安全|工地安全|禁毒|消防|安全教育体验馆|安全体验教室-贝森德(深圳)科技 | 澳门精准正版免费大全,2025新澳门全年免费,新澳天天开奖免费资料大全最新,新澳2025今晚开奖资料,新澳马今天最快最新图库-首页-东莞市傲马网络科技有限公司 | 拖链电缆_柔性电缆_伺服电缆_坦克链电缆-深圳市顺电工业电缆有限公司 | 浙江栓钉_焊钉_剪力钉厂家批发_杭州八建五金制造有限公司 | 合肥钣金加工-安徽激光切割加工-机箱机柜加工厂家-合肥通快 | 浙江建筑资质代办_二级房建_市政_电力_安许_劳务资质办理公司 | 危废处理系统,水泥厂DCS集散控制系统,石灰窑设备自动化控制系统-淄博正展工控设备 | 面粉仓_储酒罐_不锈钢储酒罐厂家-泰安鑫佳机械制造有限公司 | 脑钠肽-白介素4|白介素8试剂盒-研域(上海)化学试剂有限公司 | 明渠式紫外线杀菌器-紫外线消毒器厂家-定州市优威环保 | 专业的压球机生产线及解决方案厂家-河南腾达机械厂 | 解放卡车|出口|济南重汽|报价大全|山东三维商贸有限公司 | 亿立分板机_曲线_锯片式_走刀_在线式全自动_铣刀_在线V槽分板机-杭州亿协智能装备有限公司 | 一体化隔油提升设备-餐饮油水分离器-餐厨垃圾处理设备-隔油池-盐城金球环保产业发展有限公司 | 注塑_注塑加工_注塑模具_塑胶模具_注塑加工厂家_深圳环科 | 上海软件开发-上海软件公司-软件外包-企业软件定制开发公司-咏熠科技 | 猪I型/II型胶原-五克隆合剂-细胞冻存培养基-北京博蕾德科技发展有限公司 | 杭州高温泵_热水泵_高温油泵|昆山奥兰克泵业制造有限公司 | 报警器_家用防盗报警器_烟雾报警器_燃气报警器_防盗报警系统厂家-深圳市刻锐智能科技有限公司 | 厂房出租_厂房出售_产业园区招商_工业地产 - 中工招商网 | 常州减速机_减速机厂家_常州市减速机厂有限公司 | 万濠投影仪_瑞士TRIMOS高度仪_尼康投影仪V12BDC|量子仪器 | 「安徽双凯」自动售货机-无人售货机-成人用品-自动饮料食品零食售货机 | 污水提升器,污水提升泵,污水提升装置-德国泽德(zehnder)水泵系统有限公司 | 单级/双级旋片式真空泵厂家,2xz旋片真空泵-浙江台州求精真空泵有限公司 | 泰来华顿液氮罐,美国MVE液氮罐,自增压液氮罐,定制液氮生物容器,进口杜瓦瓶-上海京灿精密机械有限公司 | 桨叶搅拌机_螺旋挤压/方盒旋切造粒机厂家-无锡市鸿诚输送机械有限公司 | 污泥烘干机-低温干化机-工业污泥烘干设备厂家-焦作市真节能环保设备科技有限公司 |